Innovation and Reliability Since 1980

Quantum V11

Welcome to Quantum, a periodic e-newsletter. Quantum is designed to keep you up to speed on applications, case histories and evolutions of quantum magnetometers in a variety of disciplines.

TOPAirborne Developments

New version of redesigned complete airborne system GSMP-35AM with VLF option

GEM’s Potassium sensors provide the highest sensitivity available in the industry. The new tri-axial bird uses the larger volume (70 mm) sensors that are specifically designed for low-gradient applications such as exploration for diamonds, gold, silver, platinum & palladium, which map geologic structures that are weakly magnetic and may have concentrated precious metals.

GEM’s R&D team made successful efforts to modernize Airborne System. The new bird has maximized sensitivity of sensor location, redesigned electronics and dismountable elements for easy transportation.

High sensitivity (0.0007 nT) together with high sampling rate (20 readings per second) allows you to make very detailed mapping.

Using GEM’s Complete Airborne System you will receive:

  • High definition range of multi-sensors configurations (Magnetometer, Vertical Gradient or Tri-Axial Magnetic Gradiometer)
  • TRA series Radar Altimeter
  • 20 Hz DGPS with SBAS (WAAS / EGNOS / MSAS) and OmniStar (Subscription is not included)
  • GEM Data Acquisition Software with real time Data and altitude display
  • All Weather Highest sub-pico Tesla Sensitivity
  • VLF option

https://webtest.gemsys.ca/PDFDocs/GEM Airborne Solutions.pdf

For more info click here
Request for Quotation click here

TOP

New Airborne GSM-90AV VLF-EM System

GThe VLF-EM system is a two frequency multi-component receiver that measures the in-phase and quadrature-phase fields from two separate radio transmitters in the VLF frequency range (e.g. 15-30 kHz). Such measurements can identify low conductance structures containing sulphide-bearing fluids rich in precious metals.

The GSM-90AV VLF-EM is a state-of-the-art airborne system that acquires data simultaneously from up to 2 transmitter frequencies. Data include in-phase, out-of-phase, horizontal component (x), vertical component (y) and field strength in pT.

With data quality exceeding standard VLF instruments, GSM-90AV represents a unique blend of physics, data quality, operational efficiency, system design, and options that clearly differentiate it from other VLF systems.

A very low frequency (VLF) investigation is well suited to the location of geologic faults (and approximating their altitudes), some types of geologic contacts, and buried conductive bodies including water-bearing faults. The VLF-EM frequency method is a passive system as it utilizes a fixed position transmitter broadcasting a frequency between 15 and 30Kz.

In a VLF investigation, the magnetic field components of the transmitted signal are measured.

This method can delineate contrasts in conductivity at depth and is used in the search for contacts, faults, mineralized bodies, overburden, fractures, voids and for a variety of other purposes, including the location of utility lines and sitting of water wells.

Targets are of two primary types:

  • Linear trends of considerable length that are more than 30 degrees from the horizontal
  • Broader zones of lateral changes in conductivity related to such features as a plumes or alteration zones

https://webtest.gemsys.ca/PDFDocs/GSMP35A Spec.pdf

For more info click here
Request for Quotation click here

Archaeology

Archaeologists are increasingly looking at remote sensing methods as techniques to explore sites with minimum disruption to the surroundings. This work is delivering new means of mapping prehistoric and historic sites in three dimensions rather than traditional two-dimensional methods. Magnetics is a primary remote sensing technique that offers both ease-of-use and cost efficiency. Main benefits lie in the ability to resolve details non-invasively, the wide range of artifacts and cultural objects that are detectable, and the low-cost of magnetics in comparison to other methods.

TOP

Updated with new discoveries

New extended 2008 version of a book named Magnetic Surveying in Archeology: More than 10 years of Using The Overhauser GSM-19 Gradiometer where Tatyana N. Smekalova takes you in a journey of the practical aspects of magnetic surveys for the investigation of various archaeological sites.

Archaeologists will definitely have an interest in this new work produced by researchers in Russia, Denmark, Ukraine, Greece, Syria, Norway, and Egypt over the last 12 years. The book begins with an overview of methods of magnetic surveying followed by a description of magnetometers. The remainder of the book provides case histories from many sites across Africa, the Middle East and Europe but general lessons may also be applicable to other investigations in other parts of the world.

Archaeology Book

For more info click here
Request for Quotation click here

Magnetic Observatories

Each year, earthquakes injure more than 17,000 people and cause more than $40 billion in property and environmental damage globally. In looking for ways to mitigate these losses, researchers are investigating different methods, including seismic, strong motion, GPS, electromagnetic, magnetic, radon and others.

TOP

New installation in Oaxaca, Mexico

GEM has completed new experimental magnetic observatory installation in Oaxaca, Mexico. The system consists of SuperGradiometer and dIdD instruments designed for earthquake research and prediction.

The main goals of the project were establishing reference conditions to detect magnetic precursors of earthquakes based on known precursors to eliminate the influence of diurnal variations of magnetic field, need for a high sensitivity measurement of components was perceived. Ergonomic design, high sampling rate, flexibility to enable real-time transmission to satellite and phone links, etc. help to keep real-time data. Ruggedness is assured through rigorous testing and the system is covered by the industry’s longest and most comprehensive warranty (2 years).

GEM’s SuperGradiometer is based on the Potassium SuperGradiometer system and designed with data quality, high gradient sensitivity and elimination of cultural noise. Data quality is ensured through ultra-high sensitivity magnetic gradiometer, which leads the industry (0.05 pT @ RMS at a sampling rate of 1 Hz) and precision sensor design. The SuperGradiometer can achieve gradient sensitivities of 1fT/m (10-15 T/m) with a sensor spacing of 50 m – a major advantage over traditional long-baseline measurements (total field with reference station for removal of diurnals), witch have sensitivities on the order of 1nT. The SuperGradiometer also minimizes cultural noise from nearby infrastructure that improves measurement results.

GEM’s Potassium Suspended dIdD (delta Inclination / delta Declination) vector instrument is designed for obtaining high resolution total field and variability measurements. Potassium Suspended dIdD comprises a revolutionary 35 mm Potassium sensor (2.5pT sensitivity @ 1Hz) with a bidirectional set of bias coils.

Visit our website and find more information about SuperGradiometer
https://webtest.gemsys.ca/apps_earthquake_research.htm

TOP

Network for Magnetic Observatories

GEM developed a new system for Magnetic Observatories designed to set up several magnetometers to a network for the monitoring and analysis of the magnetic field of the Earth. The real time data can be used for earthquake research, volcanology, space studies and mineral exploration.

It is possible to connect several magnetometers to one network, so the system can be managed remotely. You can operate and manage the network and GEM magnetometers over the LAN, WAN or Internet and replace dedicated PCs and lengthy serial cables with fast and reliable networking technology. This remote access capability increases efficiency, saves you time and money while providing easier management from any browser, anywhere at any time.

For more info click here

TOP

New Suspended dIdD Potassium System

GEM introduced the dIdD (delta Inclination / delta Declination) Potassium vector system for high precision results in obtaining total field and variability measurements. The high sensitivity of Potassium sensor (0.05 nT/Hz1/2@ 1 sec) aprovides high speed measurements. The Suspended dIdD comprises a small diameter (250 mm), spherical Potassium sensor with a bidirectional set of bias coils. Data is acquired directly to a GEM Potassium magnetometer.

The Suspended dIdD simplifies the set-up of magnetic observatory installations by eliminating the need for fluxgate magnetometers and thermally insulating structures. In addition, the new system minimizes ongoing system calibrations, which, in turn, frees personnel to concentrate on more essential tasks (such as interpreting and understanding data).

These important new benefits are achieved through system design:

  • Temperature coefficients that reduce drift to less than 0.1 nT / °C (compared with 0.5 nT / °C for high-end fluxgate magnetometers)
  • Physical suspension of the Potassium sensor (shown experimentally to contribute to reduced drift)
  • Long term drifts that are less than 2 nT / year – matching or exceeding the best component measurement at any observatory and Suspended dIdD system

For more info click here

Request for Quotation: SuperGradiometer click here
Request for Quotation: Suspended dIdD click here

Ground Developments

As ground magnetics is one of the most-frequently employed and effective geophysical methods applied to mineral exploration, GEM continues to implement new strategies for enhancing measuring techniques and results.

Our Research and Development team has led to the development of a new generation of Potassium magnetometers GSMP-35 version 8 designed to assist exploration groups and contractors acquire, high-quality magnetic results.

TOP

New release of GSMP-35 version 8 backpack mounted Potassium magnetometer / gradiometer

GEM is releasing a new version of its GSMP-35 optically pumped Potassium magnetometer (K-Mag) designed to provide backpack-based, hands-free operation while acquiring high sensitivity ground-based magnetics data. The first presentation of the instrument will take place at PDAC 2009 (March 1-4, in Toronto).

The main features of GSMp-35 include:

  • Low power consumption (16 hours of continuous operation)
  • Very high sensitivity
  • Light weight
  • Compact design
  • New introductory price

The system eliminates the use of supporting sensor poles (with the backpack), thereby providing convenience and greater efficiency during survey operations (with the console).

The new K-Mag technology also delivers sensitivity and high sampling (20 times / second) for mapping of subtle geologic signals. The system’s high gradient tolerance and higher range of measurement (up to 3 Gauss, optional) is especially useful for exploring in areas with iron formations, magnetite outcrops, and other similar targets.

The new K-Mag will give you the following advantages:

  • Sensitivity 0.0025 nT @ 1 Hz
  • Resolution 0.0001 nT
  • Absolute Accuracy +/- 0.1 nT
  • Gradient Tolerance 30000 nT/m
  • Sampling Rate 1, 5, 10, 20 Hz
  • Electronics box weight 0.63 kg
  • Electronics box size 229mm x 56mm x 39mm

https://webtest.gemsys.ca/PDFDocs/GSMP-35.pdf

For more info click here
Request for Quotation click here

TOP

New design of our website. Please take a look and express your opinion at webtest.gemsys.ca

At GEM we like to hear from our customers. If you have any suggestions, commendations, complaints, great ideas, industry-related articles, testimonials, or questions of any type we would love to hear from you. We guarantee a prompt respond.

Visit webtest.gemsys.ca

TOP

GEM on the road, upcoming events

  • SME 2009
    • February 22-25, Denver, CO, USA
    • Colorado Convention Centre, Booth # 148
  • PDAC 2009
    • March 1-4, Toronto, Ontario, Canada
    • Metro Toronto Convention Center, Booth # 802
  • 22nd Annual SAGEEP 2009
    • March 29-April 2, Fort Worth, TX, USA
    • Renaissance Worthington Hotel, Booth # 5
  • Society for American Archaeology 74th Annual Meeting 2009
    • April 22-26, Atlanta, GA, USA
    • Atlanta Marriott Marquis, International Hall – South, Booth # 508
  • 71th EAGE Conference and Exhibition 2009
    • June 8-11, Amsterdam, The Netherlands
    • Amsterdam RAI Building, Booth # 1001
  • SEG Annual Meeting 2009
    • October 25-30, Houston, TX, USA

TOP

Important Note: Our goal is to only communicate with people who would like to hear from us. If you would like to stop your subscription, please click here. If you have received this message through a colleague and would like to be our subscriber, please click here.

For any comments or questions about our e-Newsletter Please contact: shannon.kadoski@gemsys.ca

Copyright 2007-2009. GEM Systems, Inc. Advanced Magnetometers. All rights reserved with the exception of organizations that have contributed links to this issue. Our thanks to the contributors who have made this edition possible, and who are identified in the text of related articles or through their company websites. Note that some quotes relating to industry-specific trends may have been obtained from public-domain sources, and are not intended to promote GEM Systems, Inc. Other examples may not necessarily reflect GEM products; rather these examples are intended to illustrate the use of magnetics and magnetometry for selected applications.

BACK

REQUEST A CALLBACK

If you would like to receive a callback from GEM Systems.

Name*
Phone*
Email*
Comments

Please select the Star and click the Submit button.

Refresh
  Submit
Please wait...

REQUEST A QUOTE